Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

best way to report +/- material on individual points on a constructed circle

Shawn 3 dage siden i Metrology Software / PC-DMIS 0

best way to report +/- material on individual points on a constructed circle

0

Quickly turn on and off pathlines?

Could a shortcut key be created or a quick button to turn on and off pathlines in a program? 

+3

Add the option to report out postion of both start and end pts of a cylinder instead of only the worst end. Legacy had this option but the GD&T reporting does not.

bman 2 år siden i Metrology Software / PC-DMIS opdateret af natanderson 4 uger siden 1

By showing both it gives a good indication of how angled the cylinder may be.

0

some terminology mistakes in Chinese version

sau_zhyf 4 uger siden i Metrology Software / PC-DMIS 0

In the Chinese version, the following terminologies do not match the Chinese national standard:

English terminologies
Feature
Plus Tolerence
Minus Tolerance
Terminologies in Chinese PC-DMIS
特征
上公差
下公差
Terminologies in GB
要素
上极限偏差
下极限偏差
0

Separate scanning parameters from probing parameters

timo grimm 1 måned siden i Metrology Software / PC-DMIS opdateret af Guillermo 1 måned siden 1

When changes are made to scan parameters such as point density

all other probe parameters are also automatically entered in the program.

However, if parts are measured with different measuring machines but the same program, the stored probe parameters must not be changed.

As this is not possible, the probe parameters must be adjusted each time in the program.

Scanning parameters should therefore be separated from the probe parameters, as is the case in other areas.

0

Implement support of a compound datum made of two non coaxial circles.

natanderson 2 måneder siden i Metrology Software / PC-DMIS opdateret af nrowland 1 måned siden 3

Example A is a plane, B and C are two circles laying in plane A. I need to evaluate GD&T relative to A|B-C. B-C should be treated a as pattern. ref case #00757938

Note: B and C are measured on a thin glass lens with a Vision probe on an Optiv Reference machine: they are 2D and cannot be measured as cylinders.

This functionality is supported in other metrology software. This is very frustrating and embarrassing for my customers.

0

PCDMIS admin panel

Solomon 1 måned siden i Metrology Software / PC-DMIS opdateret af Aaron Baldauf 1 måned siden 1

Hello PCDMIS gurus and devs.

I would appreciate if PCDMIS had admin panel where I could define all settings once and then point this admin panel to every computer where installation of PCDMIS exists this way If I wanted to change say for example speed of all machines or some other generic settings it would be done from one panel. For example layout of buttons, speed of 3D CMM, loading colors for highlighting code etc. 

+1

Adding comment to assign command

Mick Hinton_53 2 måneder siden i Metrology Software / PC-DMIS 0

You should be able to add a comment to the end of an assign line of code.

For example, currently the code is

ASSIGN/V1=10

it would be good if you could add a comment at the end to help with editing the program by adding $$ at the end, example

ASSIGN/V1=10 $$ diameter of hole 1

ASSIGN/V2=20 $$ diameter of hole 2



Kundesupport af UserEcho