Hexagon Measurement      Systems

No matter what Hexagon measurement equipment or software you use, we want to hear your ideas and suggestions on how we can improve.

  • Your feedback and voting will benefit the majority of users.
  • You have 10 votes which you can allocate to your own or other users ideas.
  • We will focus on trying to realize the top voted items in our future products.

Thanks for your assistance in helping us shape the future.

0

Special License Required for TubeShaper?

pohneck 1 jaar geleden in Metrology Software / TubeShaper 0
0

Multiple Routine Windows

Nathan S 2 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door Cristopher Chingwa 1 jaar geleden 1

Be able to have more than one routine open beside each other. I know you can open different windows, but you can't have them beside each other. I would like to be able to have two different routines open beside each other with the same software version. So, if I want to copy some features from one routine, I can easily implement them into the other one without changing my entire screen. 

0

Move Point Feature jog mode offline

remy r 2 jaar geleden in Metrology Software / PC-DMIS 0

Add a jog button to move the point in off line mode

to be easier to add clerance point, jump jigs, avoid collision, etc

thanks

Image 542

0

Be able to see the coordinates of the mouse pointer

Sara 2 jaar geleden in Metrology Software / PC-DMIS bijgewerkt door Kingsld1 2 jaar geleden 1

When I have used the scanner, I would like to see the coordinates of the pointer.

If I could, after defining the koordinatsystem, it would be very easy to check some dimensions just by hovering the pointer abow the cloud.

0

Put (*) sign to every probes' tips after Lower Matrix

Utku 2 jaar geleden in Metrology Software / PC-DMIS 0

Hello,

After Lower Matrix is done, only "master" probe's tips are using (*) -uncalibrated- sign. Other probes' tips remain unchanged. This looks like "only master probes' tips must be calibrated and other probes' tips are ready to use". Yet this is false. I recommend to put (*) sign to every probes' tips after lower matrix is done. 

Best Regards. 

0

Give the ability to mute hits on auto-features.

RedgeXIII 2 jaar geleden in Metrology Software / PC-DMIS 0

Often using an auto-plane with spiral movement, asymmetrical hole patterns cause hits to land in a hole. Adjusting auto-planes manually is not fun when any slight changes require that the hits be regenerated, and you have to start back from scratch. With the ability to mute hits, you can adjust the hits by hit count and spacer, then simply mute any hits that conflict with other features.

0

Make the Parameter "Displayprecision" adjustable for Report Commands

alexander weil 2 jaar geleden in Metrology Software / PC-DMIS 0
At the Moment it is not possible to adjust the Displayprecision of the Reports, when the Reports are created out of the Report Command --> Print Command.
It will always use the last setting. For example: If I switch inside my PP from Displayprecision "3" to "2" and back to "3" it will use the setting "3" for the whole Report.  I know this is "works as designed" but I kindly ask to make this Parameter available.
Reason I am asking this is that it is not possible to create two Reports out of one Routine (as we all know). Therefore I have to create the Report as a Report command and the use "Copy File" command in PC-DMIS to duplicate the Report. Unfortunately the Report command Report does not take over all my Displayprecision Settings as described above.
Alternatively you could make the Function available to Print the standard Report twice. For standard Reports created with "File --> Printer --> Printer Report Setting" Displayprecision works fine.
On the other Hand: When I set up different Displayprecision settings inside my Routine, why wouldnt I see it on my Report, no matter how it has been created?